1-1
Operating Instructions
Drive Operational Requirements:
Hydraulic System:
Closed center, pressure compensated or load
sensed systems only
Drive will not operate on open-centered
hydraulic systems
Minimum Hyd. Pressure: 2250 psi
Maximum Hyd. Pressure: 3000 psi
Maximum Required Flow: 8.5 gpm
Electrical System:
Voltage: 12 volt DC
Amperage: 4 amperes
Tractor Hookup
Hydraulics:
1) Connect pressure hose (P) to retraction outlet
2) Connect motor return hose (T) to motor return port (if available) or to
extension outlet.
3) Set flow rate at maximum.
4) If tractor is equipped with electro-hydraulic valves, set timer to “constantflow.
Electrical:
1) Power can be connected in two different manners:
a) Power port adaptor (PN 19676)